Putting Brick on Flashing Auburn NY

Many architects in Auburn recommend that no mortar be used for the brick course that is directly on the flashing over a shelf angle. If mortar is not used on the flashing, what keeps the brick from sliding off the angle?

Cook'S Construction & Restoration Consultants, Inc.
800-922-9270
8091 High Street
Montezuma, NY
DAVE MARION CARPENTRY INC
315-364-8578
2492 FRY ROAD
AURORA, NY
R.L. Gant Construction
615-686-2933
3935 Pheasant Dr
Nashville, NY
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Minnesota Mitigation (952) 938-1006 Radon Removal Testing & Remediation St. Paul-Minneapolis Mn
952-938-1006
1912 Suburban Ave.
Saint Paul, NY
Cramer Home Inspection Group, Inc.
877-255-2147
101 Cayuga St
Seneca Falls, NY
Expert Chimney Services, Inc
315 469 5004
4800 McDonald Rd
Syracuse, NY
New World Construction, Inc.
410-366-0444
722 Dulaney Valley Road, Suite 284
Towson, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Mike Mattera Trucking & Crane Ser.
845-706-3085
PO Box 688
Saugerties, NY
Data Provided by:
 
Provided By:

Putting Brick on Flashing

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: May 1, 2005

Many architects recommend that no mortar be used for the brick course that is directly on the flashing over a shelf angle. If mortar is not used on the flashing, what keeps the brick from sliding off the angle?

When mortar is placed on flashings on foundations, it is normally used to level the lowest course. Even if the flashing is bonded to the shelf angle, the mortar does not bond well to either plastic or metal flashing.

After the masonry wall is installed and the mortar cured, the wall above the shelf angle acts as one rigid element. Because the exterior wythe is anchored to the backup with many ties, the wall is prevented from moving laterally. The shelf angle is not intended to provide lateral support, but instead its purpose is to create vertical support. The first tie is generally located at a height above the shelf angle equal to half the typical tie spacing. This placement provides sufficient lateral restraint at the lower portion of the wall.

Some friction occurs between the brick and flashing; however, this action is generally not relied on to provide resistance for lateral loads. As long as the shelf angle supports at least two-thirds of the wall width, the wall should be stable during construction as well.

I typically do not recommend using mortar on the top surface of the flashing since it slows down drainage of water from the wall.

Click here to read full article from Masonry Construction